{"id":40302,"date":"2023-03-21T10:10:41","date_gmt":"2023-03-21T10:10:41","guid":{"rendered":"https:\/\/m5j0n6nk9p.onrocket.site\/products\/valves\/gate-and-globe-valves\/industrial-gate-and-globe-valves\/valvula-de-globo-baixa-pressao\/"},"modified":"2023-05-12T11:41:15","modified_gmt":"2023-05-12T10:41:15","slug":"low-pressure-globe-valves","status":"publish","type":"page","link":"https:\/\/klinger.pt\/en\/products\/valves\/gate-and-globe-valves\/industrial-gate-and-globe-valves\/low-pressure-globe-valves\/","title":{"rendered":"LOW PRESSURE GLOBE VALVES"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:400px\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"350\" height=\"483\" src=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Valvula-de-Globo-BP-pag.webp\" alt=\"LOW PRESSURE GLOBE VALVES\" class=\"wp-image-39594\" srcset=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Valvula-de-Globo-BP-pag.webp 350w, https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Valvula-de-Globo-BP-pag-217x300.webp 217w\" sizes=\"(max-width: 350px) 100vw, 350px\" \/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:700px\">\n<h1 class=\"wp-block-heading\">LOW PRESSURE GLOBE VALVES<\/h1>\n\n\n\n<h3 class=\"wp-block-heading\">KAD-GBF<\/h3>\n\n\n\n<p>Low Pressure <strong>Globe Valves for general purpose<\/strong>&nbsp;are primarily used for process throttling.<br>They can also be considered general purpose flow control valves used in high temperature applications.<br>Globe Valves are given their name due to their spherical body which is like a globe.<br>The two halves of the body are separated by an internal baffle.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Features<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Cast steel body construction providing liberal strength to meet most conditions<\/li>\n\n\n\n<li>Integral yoke &amp; bonnet; Outside screw &amp; yoke, bolted bonnet<\/li>\n\n\n\n<li>Seal welded seat ring eliminates leak path behind rings and for long trouble-free service<\/li>\n\n\n\n<li>Available in fl anged end connection; butt weld end also available<\/li>\n\n\n\n<li>EN10204-3.1 Material certifi cate available<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Body material<\/h2>\n\n\n\n<p>DIN 17245 GS-C25<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Temperature<\/h2>\n\n\n\n<p>-20\u00b0C to 425\u00b0C (-4\u00b0F to 800\u00b0F)<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">PN<\/h2>\n\n\n\n<p>PN16 to PN63<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Standards<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Basic design to DIN 3356<\/li>\n\n\n\n<li>Face-to-Face acc. to DIN 3202-F2<\/li>\n\n\n\n<li>Flange Dimensions acc. to EN 1092-1<\/li>\n\n\n\n<li>Inspection &amp; test according to EN 12266-1<\/li>\n<\/ul>\n\n\n\n<p>*For non-horizontal installation, please ensure to consult with us separately, as special request must be generated to ensure proper function.<\/p>\n<\/div>\n<\/div>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Globe-Valve_KAD-GBF-PN16-F1_Data-Sheet-1.pdf\" target=\"_blank\" rel=\"noopener\" title=\"\">KAD-GBF PN16-F1 DATA SHEET (EN<\/a>)<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Globe-Valve_KAD-GBF-PN25-F1_Data-Sheet-1.pdf\" target=\"_blank\" rel=\"noopener\" title=\"\">KAD-GBF PN25-F1 DATA SHEET (EN)<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Globe-Valve_KAD-GBF-PN40-F1_Data-Sheet-1.pdf\" target=\"_blank\" rel=\"noopener\" title=\"\">KAD-GBF PN40-F1 DATA SHEET (EN)<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Globe-Valve_KAD-GBF-PN63-F2_Data-Sheet-1.pdf\" target=\"_blank\" rel=\"noopener\" title=\"\">KAD-GBF PN63-F2 DATA SHEET (EN)<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Globe-Valve-ZFA63_compressed-1.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">GLOBE VALVE ZFA63 PN63 ANGULAR DATA SHEET (EN)<\/a><\/h5>\n","protected":false},"excerpt":{"rendered":"<p>LOW PRESSURE GLOBE VALVES KAD-GBF Low Pressure Globe Valves for general purpose&nbsp;are primarily used for process throttling.They can also be considered general purpose flow control valves used in high temperature applications.Globe Valves are given their name due to their spherical body which is like a globe.The two halves of the body are separated by an [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":42534,"parent":40279,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/servicios.php","meta":{"_eb_attr":"","footnotes":""},"class_list":["post-40302","page","type-page","status-publish","has-post-thumbnail","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages\/40302","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/comments?post=40302"}],"version-history":[{"count":5,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages\/40302\/revisions"}],"predecessor-version":[{"id":40750,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages\/40302\/revisions\/40750"}],"up":[{"embeddable":true,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages\/40279"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/media\/42534"}],"wp:attachment":[{"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/media?parent=40302"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}