{"id":40294,"date":"2023-03-21T09:48:54","date_gmt":"2023-03-21T09:48:54","guid":{"rendered":"https:\/\/m5j0n6nk9p.onrocket.site\/products\/valves\/gate-and-globe-valves\/industrial-gate-and-globe-valves\/valvula-de-cunha-baixa-pressao\/"},"modified":"2023-05-12T11:55:54","modified_gmt":"2023-05-12T10:55:54","slug":"low-pressure-gate-valve","status":"publish","type":"page","link":"https:\/\/klinger.pt\/en\/products\/valves\/gate-and-globe-valves\/industrial-gate-and-globe-valves\/low-pressure-gate-valve\/","title":{"rendered":"LOW PRESSURE GATE VALVE"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:400px\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"350\" height=\"483\" src=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Valvula-de-cunha-BP-pag.webp\" alt=\"LOW PRESSURE GATE VALVE\" class=\"wp-image-39571\" srcset=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Valvula-de-cunha-BP-pag.webp 350w, https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Valvula-de-cunha-BP-pag-217x300.webp 217w\" sizes=\"(max-width: 350px) 100vw, 350px\" \/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:700px\">\n<h1 class=\"wp-block-heading\">LOW PRESSURE GATE VALVE<\/h1>\n\n\n\n<h3 class=\"wp-block-heading\">KSD-GTF<\/h3>\n\n\n\n<p>The&nbsp;<strong>bonnet<\/strong>&nbsp;of a low pressure gate valve protects the internal parts of the gate valve by providing a leak-proof seal.<br>Therefore, it can be removed for repair or maintenance.<br>Gate valves can be equipped with screw-in, union, bolted or pressure seal bonnets, depending on the application.<\/p>\n\n\n\n<p>In a&nbsp;<strong>bolted bonnet<\/strong>&nbsp;gate valve, its valve body and bonnet are bolted and flanged together.<br>Bolted bonnet gate valves are mostly used in steam piping systems: They ensure sufficient sealing in low-pressure applications.<br>Unlike threaded and union bonnet valves, the bolted bonnet connection requires a gasket to seal the joint between the body and bonnet.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Features<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Cast steel body construction providing liberal strength to meet most conditions<\/li>\n\n\n\n<li>Integral yoke &amp; bonnet; Outside screw &amp; yoke, bolted bonnet<\/li>\n\n\n\n<li>Single flexible wedge disc compensates for deformation of body due to pipe stresses<\/li>\n\n\n\n<li>Seal welded seat ring eliminates leak path behind rings and for long trouble-free service<\/li>\n\n\n\n<li>Available in flanged end connection; butt weld end also available<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Body Material<\/h2>\n\n\n\n<p>DIN 17245 GS-C25<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Temperature<\/h2>\n\n\n\n<p>-20\u00b0C to 425\u00b0C (-4\u00b0F to 800\u00b0F)<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">PN<\/h2>\n\n\n\n<p>PN16 to PN63<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Standards<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Basic design to DIN 3352<\/li>\n\n\n\n<li>Face-to-Face acc. to DIN 3202-F4<\/li>\n\n\n\n<li>Flange Dimensions acc. to DIN 2543<\/li>\n\n\n\n<li>Inspection &amp; test according to EN 12266-1<\/li>\n<\/ul>\n\n\n\n<p>*For non-horizontal installation, please ensure to consult with us separately, as special request must be generated to ensure proper function.<\/p>\n<\/div>\n<\/div>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Gate-Valve_KSD-GTF-PN16-F4_Data-Sheet-1.pdf\" target=\"_blank\" rel=\"noopener\" title=\"\">KSD-GTF PN16-F4 DATA SHEET (EN)<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Gate-Valve_KSD-GTF-PN16-F5_Data-Sheet-1.pdf\" target=\"_blank\" rel=\"noopener\" title=\"\">KSD-GTF PN16-F5 DATA SHEET (EN<\/a>)<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Gate-Valve_KSD-GTF-PN25-F5_Data-Sheet-1.pdf\" target=\"_blank\" rel=\"noopener\" title=\"\">KSD-GTF PN25-F5 DATA SHEET (EN)<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Gate-Valve_KSD-GTF-PN40-F7_Data-Sheet-1.pdf\" target=\"_blank\" rel=\"noopener\" title=\"KSD-GTF PN40-F7 DATA SHEET (EN)\">KSD-GTF PN40-F7 DATA SHEET (EN)<\/a><\/h5>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Gate-Valve_KSD-GTF-PN63-F7_Data-Sheet-1.pdf\" target=\"_blank\" rel=\"noopener\" title=\"KSD-GTF PN63-F7 DATA SHEET (EN)\">KSD-GTF PN63-F7 DATA SHEET (EN)<\/a><\/h5>\n","protected":false},"excerpt":{"rendered":"<p>LOW PRESSURE GATE VALVE KSD-GTF The&nbsp;bonnet&nbsp;of a low pressure gate valve protects the internal parts of the gate valve by providing a leak-proof seal.Therefore, it can be removed for repair or maintenance.Gate valves can be equipped with screw-in, union, bolted or pressure seal bonnets, depending on the application. In a&nbsp;bolted bonnet&nbsp;gate valve, its valve body [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":42537,"parent":40279,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/servicios.php","meta":{"_eb_attr":"","footnotes":""},"class_list":["post-40294","page","type-page","status-publish","has-post-thumbnail","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages\/40294","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/comments?post=40294"}],"version-history":[{"count":6,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages\/40294\/revisions"}],"predecessor-version":[{"id":40460,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages\/40294\/revisions\/40460"}],"up":[{"embeddable":true,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages\/40279"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/media\/42537"}],"wp:attachment":[{"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/media?parent=40294"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}