{"id":37146,"date":"2023-02-06T15:34:39","date_gmt":"2023-02-06T15:34:39","guid":{"rendered":"https:\/\/m5j0n6nk9p.onrocket.site\/products\/valves\/gate-valves\/valvula-de-cunha-elastica-flangeada\/"},"modified":"2023-03-31T10:28:32","modified_gmt":"2023-03-31T09:28:32","slug":"resilient-seat-gate-valve","status":"publish","type":"page","link":"https:\/\/klinger.pt\/en\/products\/valves\/gate-and-globe-valves\/water-gate-valves\/resilient-seat-gate-valve\/","title":{"rendered":"RESILIENT SEAT GATE VALVE"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:400px\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/02\/Valvula-de-Cunha-Elastica-Flangeada-Com-Atuador-1.webp\" alt=\"RESILIENT SEAT GATE VALVE\" class=\"wp-image-37108\" width=\"216\" height=\"320\" srcset=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/02\/Valvula-de-Cunha-Elastica-Flangeada-Com-Atuador-1.webp 313w, https:\/\/klinger.pt\/wp-content\/uploads\/2023\/02\/Valvula-de-Cunha-Elastica-Flangeada-Com-Atuador-1-202x300.webp 202w\" sizes=\"(max-width: 216px) 100vw, 216px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"444\" height=\"444\" src=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/02\/Valvula-de-Cunha-Elastica-Flangeada-Sem-Atuador.webp\" alt=\"RESILIENT SEAT GATE VALVE\" class=\"wp-image-37110\" srcset=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/02\/Valvula-de-Cunha-Elastica-Flangeada-Sem-Atuador.webp 444w, https:\/\/klinger.pt\/wp-content\/uploads\/2023\/02\/Valvula-de-Cunha-Elastica-Flangeada-Sem-Atuador-300x300.webp 300w, https:\/\/klinger.pt\/wp-content\/uploads\/2023\/02\/Valvula-de-Cunha-Elastica-Flangeada-Sem-Atuador-150x150.webp 150w\" sizes=\"(max-width: 444px) 100vw, 444px\" \/><\/figure>\n<\/div>\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"479\" height=\"69\" src=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/02\/BVP70RVALVULADECOMPUERTACETIPOBRIDASS14152.jpg\" alt=\"RESILIENT SEAT GATE VALVE\" class=\"wp-image-37116\" srcset=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/02\/BVP70RVALVULADECOMPUERTACETIPOBRIDASS14152.jpg 479w, https:\/\/klinger.pt\/wp-content\/uploads\/2023\/02\/BVP70RVALVULADECOMPUERTACETIPOBRIDASS14152-300x43.jpg 300w\" sizes=\"(max-width: 479px) 100vw, 479px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:700px\">\n<h1 class=\"wp-block-heading\">RESILIENT SEAT GATE VALVE<\/h1>\n\n\n\n<p>The Resilient Seat Gate Valve is available in versions with and without actuator. Application: water transmission, water distribution network, fire protection, desalination, water treatment, irrigation, domestic connections, dams and hydroelectric power, industrial water, waste water and treatment applications.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">GENERAL FEATURES<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Range DN-40 to DN-1200<\/li>\n\n\n\n<li>100% tightness in both directions<\/li>\n\n\n\n<li>100% tested in accordance with EN 12266-1<\/li>\n\n\n\n<li>Straight, full flow, optimum flow with minimum pressure drop<\/li>\n\n\n\n<li>Packing change under pressure<\/li>\n\n\n\n<li>Flanged body cap screws<\/li>\n\n\n\n<li>Low torque values<\/li>\n\n\n\n<li>Epoxy paint 250 microns<\/li>\n\n\n\n<li>Resistance to 2,500 cycles<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">STANDARD<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Design: DIN 3352<\/li>\n\n\n\n<li>Manufacture in accordance with: EN 1074-2. \/GB\/T12232-1989<\/li>\n\n\n\n<li>Face-to-face spacing: EN 558-1 14\/15 Series (F4\/F5)<\/li>\n\n\n\n<li>Flange mounting: PN10 \/ 16 EN 1092-2, ISO 7005-2<\/li>\n\n\n\n<li>Pressure test: EN 12266-1 Grade A. GB\/T13927-1992<\/li>\n\n\n\n<li>Body: 24 bar<\/li>\n\n\n\n<li>Seat: 17.6 bar<\/li>\n\n\n\n<li>EU \/ EU Directive 2014\/68: Excluded products, article 1, \u00a7 2b up to DN-300. Risk Category I MoD. A from DN-350 to DN-600<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">WORKING CONDITIONS<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pressure ratings: 1.0Mpa\/ 1.6Mpa<\/li>\n\n\n\n<li>Working temperature: -10\u00baC + 80\u00baC<\/li>\n\n\n\n<li>Maximum allowable speed 4 m\/s according to EN1074-2<\/li>\n\n\n\n<li>Suitable media: water and neutral liquids<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">SPECIAL FEATURES<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>4 seal rings on the shaft (a total of 6 seal rings on the cover).<\/li>\n\n\n\n<li>The top 3 sealing rings can be replaced in the line under pressure when the valve is fully open.<\/li>\n\n\n\n<li>The liner sealing face achieves better sealing and lower sealing torque.<\/li>\n\n\n\n<li>Lower closing torque.<\/li>\n\n\n\n<li>Thrust washer: brass material for more reliable strength and longer life.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/02\/Ficha-tecnica-Valvula-de-Cunha-Flangeda_compressed-2.pdf\" target=\"_blank\" rel=\"noopener\" title=\"\">DATA SHEET (PT)<\/a><\/h5>\n","protected":false},"excerpt":{"rendered":"<p>RESILIENT SEAT GATE VALVE The Resilient Seat Gate Valve is available in versions with and without actuator. Application: water transmission, water distribution network, fire protection, desalination, water treatment, irrigation, domestic connections, dams and hydroelectric power, industrial water, waste water and treatment applications. GENERAL FEATURES STANDARD WORKING CONDITIONS SPECIAL FEATURES DATA SHEET (PT)<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":31751,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/servicios.php","meta":{"_eb_attr":"","footnotes":""},"class_list":["post-37146","page","type-page","status-publish","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages\/37146","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/comments?post=37146"}],"version-history":[{"count":5,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages\/37146\/revisions"}],"predecessor-version":[{"id":40453,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages\/37146\/revisions\/40453"}],"up":[{"embeddable":true,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages\/31751"}],"wp:attachment":[{"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/media?parent=37146"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}