{"id":25501,"date":"2022-08-19T13:30:33","date_gmt":"2022-08-19T12:30:33","guid":{"rendered":"https:\/\/m5j0n6nk9p.onrocket.site\/wafer\/krd-dpc-model\/"},"modified":"2023-05-09T15:15:52","modified_gmt":"2023-05-09T14:15:52","slug":"krd-dpc-model","status":"publish","type":"page","link":"https:\/\/klinger.pt\/en\/products\/valves\/check-valves\/low-pressure-check-valves\/wafer\/krd-dpc-model\/","title":{"rendered":"DUAL PLATE WAFER CHECK VALVE"},"content":{"rendered":"\n<h1 class=\"wp-block-heading\">DUAL PLATE WAFER CHECK VALVE<\/h1>\n\n\n\n<p>The dual plate wafer check valve is one of the most compact check valves.<br>This valve design is the result of attempts to provide an alternative solution to the problems associated with swing check valves.<br>Compared to a conventional swing check valve, it is much stronger, lighter and smaller in size.<br>The two plates of the dual plate check valve are hinged vertically in the center, eliminating the effect of gravity in horizontal installations.<br>When fluid enters the valve, pressure opens the flaps, stretching the spring.<br>When the valve closes, the flow cushions the plates and seat, so the risk of slamming is negligible.<\/p>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:300px\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"500\" height=\"483\" src=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/VALVULA-DE-RETENCAO-PLACA-DUPLA-PAG.webp\" alt=\"DUAL PLATE WAFER CHECK VALVE\" class=\"wp-image-39684\" srcset=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/VALVULA-DE-RETENCAO-PLACA-DUPLA-PAG.webp 500w, https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/VALVULA-DE-RETENCAO-PLACA-DUPLA-PAG-300x290.webp 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/klinger.pt\/wp-content\/uploads\/2022\/08\/Quadro-6-0.png\" alt=\"DUAL PLATE WAFER CHECK VALVE\" class=\"wp-image-25470\" width=\"257\" height=\"219\" srcset=\"https:\/\/klinger.pt\/wp-content\/uploads\/2022\/08\/Quadro-6-0.png 431w, https:\/\/klinger.pt\/wp-content\/uploads\/2022\/08\/Quadro-6-0-300x256.png 300w\" sizes=\"(max-width: 257px) 100vw, 257px\" \/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:700px\">\n<h2 class=\"wp-block-heading\">Dual Plate Wafer Check Valve KRD-DPC<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Features<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Cast steel body construction providing liberal strength to meet most conditions<\/li>\n\n\n\n<li>A choice of metal-to-metal or soft sealing<\/li>\n\n\n\n<li>Full range of pressure class and sizes<\/li>\n\n\n\n<li>Variety of body and disc materials<\/li>\n\n\n\n<li>Savings in price and installation cost compared to coventional check valves<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Temperature<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Metal seat: -29\u00b0C to 450\u00b0C<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Standards<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Basic design to API 594<\/li>\n\n\n\n<li>Face-to-Face acc. to API 594<\/li>\n\n\n\n<li>Flange Dimensions acc. to ASME B16.5<\/li>\n\n\n\n<li>Inspection &amp; test according to API 598<\/li>\n<\/ul>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/03\/Check-Valve_KRD-DPC_Data-Sheet_compressed.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">DUAL PLATE WAFER CHECK VALVE KRD-DPC DATA SHEET (EN)<\/a><\/h5>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:300px\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"270\" height=\"270\" src=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/04\/Valvula-de-retencao-duplo-prato-407A-mini.webp\" alt=\"DUAL PLATE WAFER CHECK VALVE\" class=\"wp-image-40708\" srcset=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/04\/Valvula-de-retencao-duplo-prato-407A-mini.webp 270w, https:\/\/klinger.pt\/wp-content\/uploads\/2023\/04\/Valvula-de-retencao-duplo-prato-407A-mini-150x150.webp 150w\" sizes=\"(max-width: 270px) 100vw, 270px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"400\" src=\"https:\/\/klinger.pt\/wp-content\/uploads\/2022\/08\/407A_2.jpg\" alt=\"DUAL PLATE WAFER CHECK VALVE\" class=\"wp-image-25483\" srcset=\"https:\/\/klinger.pt\/wp-content\/uploads\/2022\/08\/407A_2.jpg 400w, https:\/\/klinger.pt\/wp-content\/uploads\/2022\/08\/407A_2-300x300.jpg 300w, https:\/\/klinger.pt\/wp-content\/uploads\/2022\/08\/407A_2-150x150.jpg 150w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:700px\">\n<h2 class=\"wp-block-heading\">Dual Plate Wafer Check Valve IDP<\/h2>\n\n\n\n<p>Flange connection PN 10\/16<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Features<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Application: liquids and gases<\/li>\n\n\n\n<li>Compact<\/li>\n\n\n\n<li>Easy installation<\/li>\n\n\n\n<li>Horizontal \u2013 or vertical mounting<\/li>\n\n\n\n<li>Material: Cast iron GG25<\/li>\n\n\n\n<li>Pressure class: PN 16<\/li>\n\n\n\n<li>Disc: Stainless steel AISI 304<\/li>\n\n\n\n<li>Spring: Stainless steel<\/li>\n\n\n\n<li>O-rings: EPDM<\/li>\n\n\n\n<li>Options: House and disc in other materials; Dimensions up to DN600; Other connections and pressure stages<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Temperature<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>-10\u00baC to 100\u00baC<\/li>\n<\/ul>\n\n\n\n<h5 class=\"wp-block-heading\"><a href=\"https:\/\/klinger.pt\/wp-content\/uploads\/2023\/04\/DOUBLE-PLATE-CHECK-VALVE-407A_compressed.pdf\" target=\"_blank\" rel=\"noopener\" title=\"\">DUAL PLATE WAFER CHECK VALVE IDP DATA SHEET (EN)<\/a><\/h5>\n<\/div>\n<\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>DUAL PLATE WAFER CHECK VALVE The dual plate wafer check valve is one of the most compact check valves.This valve design is the result of attempts to provide an alternative solution to the problems associated with swing check valves.Compared to a conventional swing check valve, it is much stronger, lighter and smaller in size.The two [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":42483,"parent":25495,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/servicios.php","meta":{"_eb_attr":"","footnotes":""},"class_list":["post-25501","page","type-page","status-publish","has-post-thumbnail","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages\/25501","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/comments?post=25501"}],"version-history":[{"count":5,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages\/25501\/revisions"}],"predecessor-version":[{"id":40739,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages\/25501\/revisions\/40739"}],"up":[{"embeddable":true,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/pages\/25495"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/media\/42483"}],"wp:attachment":[{"href":"https:\/\/klinger.pt\/en\/wp-json\/wp\/v2\/media?parent=25501"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}